Product Category

Hydraulic solenoid MF1 Series

MFB1-YC AC self-rectifying solenoids for hydraulics

Inquiry Now >

Application:
The series of AC, DC solenoids for hydraulic valves apply to control circuits of AC 50Hz, voltage up to 220V and of single phase DC power, voltage up to 220V, and are used as power units for joint-designed type hydraulic-pressure back pressure controlled valves in the country.

Specifications

parameters\type

MFZ1-2.5YC

MFB1-2.5YC

MFZ1-4YC

MFB1-4YC

MFB1-5.5YC

MFZ1-5.5YC

MFZ1-7YC

MFB1-7YC

Rated voltage(V)

12 24 110 220

110 220

12 24 110 220

110 220

110 220

12 24 110 220

12 24 110

110 220

Rated Force(N)

≥25

≥25

≥40

≥40

≥55

≥55

≥70

≥70

Rated Stroke(mm)

3

3

6

6

4

4

7

7

Full Stroke(mm)

≥6.2

≥6.2

≥12

≥12

≥8.5

≥8.5

≥10.5

≥10.5

Consumption Power(W)

≤26

≤26

≤40

≤40

≤40

≤40

≤40

≤40

Endurable oil pressure(MPa)

6.3

6.3

6.3

6.3

6.3

6.3

6.3

6.3

Operation frequency(T/h)

7200

7200

7200

7200

7200

7200

3600

3600

External Shape and Installing Dimension
Hydraulic solenoid MF1 Series

Specifications

Dimensions(mm)

Installation dimensions(mm)

Model

A

H

d1

D

a

d

L1

L2

MFZ1-2.5YC

47.5

76

Ф4

Ф8.5

38±0.2

Ф4.5

3±0.1

8

MFB1-2.5YC

47.5

76

Ф4

Ф8.5

38±0.2

Ф4.5

3±0.1

8

MFZ1-4YC

55.6

100

Ф7

Ф12.5

45±0.2

Ф5.5

6±0.1

13

MFB1-4YC

55.6

100

Ф7

Ф12.5

45±0.2

Ф5.5

6±0.1

13

MFZ1-5.5YC

55.6

100

Ф7

Ф12.5

45±0.2

Ф5.5

4±0.1

11

MFB1-5.5YC

55.6

100

Ф7

Ф12.5

45±0.2

Ф5.5

4±0.1

11

MFZ1-7YC

72.6

111

Ф8

Ф13

60±0.2

Ф6.5

7±0.1

10

MFB1-7YC

72.6

111

Ф8

Ф13

60±0.2

Ф6.5

7±0.1

10

 

 

Note: 

Electromagnet adopts plug bases meeting the requirements of the ISO4000 standard. The user can choose at his needs between the two specifications, including plug base with indicator light and plug base without indicator light. The voltage specification of the plug base with indicator light should conform to the voltage specification of the electromagnet itself.

The manual jogger of the electromagnet should be controlled by hand only in the debugging or critical situation. However, when the backing pressure of the system is pretty high and difficult to adjust, the user should use the cross head driver to slowly push the manual jogger instead of using impact force so as to avoid destroying the manual jogger and the surface of the direction hole which will cause the electromagnet to leak the oil and unable to reset.

When the electromagnet is used Bi-direction, it should be insured that the two electromagnets cannot be electrified at the same time so as to avoid the malfunction of the electromagnet.

Overcurrent protection system should be used in the connection part between electric control system and electromagnet so as avoid burning the electromagnet and electronic control units under improper condition.

Explanation Of Sample:

If client have special requirements,we can adjust the connect dimension,the extended length of push pin,and the supply voltage between solenoids and valve body.

Characteristic curve for reference only.

If the application is beyond the catalogue,please contact with us.

 

The main performance parameter is obtained in the conditions of lab.Finally explanation and changing of the parameters by Tonly.

+86-574-88452652